Grid Services Control

FCR/aFRR/Voltage Support Control Room

This control room view models real-time frequency regulation, voltage support, and reserve services. It visualizes the end-to-end control loop — from grid signals to algorithmic dispatch to BESS response — including event logs and performance compliance.

What it visualizes

  • grid frequency and tolerance band monitoring
  • service allocation across FCR/aFRR/voltage/reactive/reserve
  • control loop latency breakdown and response time KPIs
  • event log with activations and stabilization actions
  • ancillary services accuracy and penalty risk indicators
  • resilience capabilities (islanding, black-start, autonomous failover)

Used for

  • operating ancillary services with audit-ready performance evidence
  • validating response-time constraints and redundancy logic
  • minimizing penalty exposure through compliance monitoring

Grid Services Control

Frequency Regulation & Voltage Support Management • Real-Time Balancing

Real-Time Grid Frequency

49.98 Hz
Grid Frequency
49.9550.0050.05
Deviation-0.02 Hz
Tolerance Band±0.05 Hz
Response Time128 ms
Stability StatusStabilized
Active Regulation Mode
Primary Frequency Control (FCR)

Active Service Allocation

Dynamic Reallocation: Enabled
Total Capacity Available87 MW
FCR18 MW
aFRR22 MW
Voltage Support8 MW
Reactive Power6 MW
Spinning Reserve10 MW
Idle / Flexible23 MW
Committed Services
64 MW
Utilization Rate
73.6%

Voltage Support & Reactive Power

Grid Voltage
398 V
Nominal 400 V
Reactive Power Injection
+3.2 MVar
Capacitive mode
Power Factor
0.98
Leading
Voltage Stability Index
8.9 / 10
Highly stable

Control Loop Visualization

Grid Signal
0 ms
Control Algorithm
8 ms
Dispatch Command
42 ms
BESS Response
132 ms
Grid Stabilization
Signal Processing Latency
8 ms
Control Execution Time
42 ms
Full System Response
132 ms

Real-Time Event Log

14:23:45
Frequency dip detected (49.92 Hz)
FCR dispatch: +4 MW
14:18:32
Voltage fluctuation in Node 3
Reactive injection: +2.1 MVar
14:12:18
aFRR activation signal received
Ramp-up: 6 MW in 180s
14:05:09
Grid stabilized
Return to standby mode
13:58:24
Voltage spike detected (404 V)
Reactive absorption: -1.8 MVar
Events Today
247

Ancillary Services Performance

FCR Accuracy (30d)99.4%
aFRR Activation Compliance100%
Missed Activation Events0
Penalty Incidents0
Average Ramp Speed0.8 MW/s
Total Activations
1,247
Avg Response Time
124 ms

Resilience & Failover Logic

Grid Islanding Capability
Enabled
Black-Start Support
Available
Backup Power Priority
Critical Loads First
Failover Mode
Autonomous
Grid Resilience Active
All redundancy systems operational. Auto-recovery enabled.

Flexibility Utilization Index

FCR22%
aFRR27%
Voltage Support9%
Spinning Reserve14%
Idle Capacity28%
Overall Utilization
72%
Flexibility Score
9.2/10