Event-Driven Distributed Energy Control

Detection → Event Processing → Decision Engine → Execution; Kafka; Safety

Ein Echtzeit-Orchestrierungs-Model für Grid-Interactive-DER: Detection → Event Processing → AI Decision Engine → Automated Execution, mit Safety Constraints, Audit Trails und SCADA Override. Designed für High-Throughput, Low-Latency-Dispatch unter Regulatory Compliance.

Prototyp-Umgebung. Illustrative Daten.

Visualisiert

  • Trigger Patterns (Peak Load, PV Surplus, Grid Instability, Price Spikes)
  • Kafka-Based Routing mit Priority und Exactly-Once Semantics
  • Constraint-Based Optimization (SOC Floors, Thermal, Ramp Rates, Grid Codes)
  • Execution Actions (Dispatch, EV Priority, Islanding, Feed-In Optimization)
  • Tenant Isolation und Portfolio-Level Aggregation

Verwendet für

  • Design von High-Throughput, Low-Latency-Dispatch-Systems
  • Validierung von Event-Driven-Control-Logic und Safety Constraints
  • Optimierung von Real-Time-Orchestration unter Regulatory Compliance
Prototype 03

Event-Driven Distributed Energy Control Architecture

Real-Time Distributed Energy Orchestration Model / Grid-Interactive Control System

System State
Grid-Connected
Operation Mode
Optimization
Event Throughput
12,400/sec peak
Processing Latency (p95)
8ms
Active Tenants
12
Safety Status
All Clear
Layer 1 – Detection
Layer 2 – Event Processing
Layer 3 – Decision Engine
Layer 4 – Execution
Detection Layer
Peak Load Detected
Load > 4.8 MW for > 120s
Transformer temp > threshold
Frequency deviation ±0.2 Hz
Event Processing
Energy Dispatch Event
Priority:High
Grid stability check passed
Decision Engine
AI Optimization
Constraints:
SOC floor 25%
Thermal limits
Ramp rate compliance
Execution Layer
Battery Discharge
2.4 MW / 15 min window
Ramp rate 0.3 MW/s
SOC floor 25%
-2.4 MW demand
Detection Layer
Solar Overproduction
PV Output > Forecast +12%
Storage SOC < 80%
Market price < €0.05/kWh
Event Processing
Storage Optimization Event
Priority:Medium
Market signal confirmed
Decision Engine
Load Forecasting
Constraints:
Charge rate limits
Grid feed-in cap
Price threshold
Execution Layer
EV Charging Priority
1.8 MW allocation
Dynamic scheduling
Price-based dispatch
+1.8 MW storage
Detection Layer
Grid Instability
Frequency < 49.8 Hz
Voltage deviation > 8%
External DSO emergency signal
Event Processing
Load Redistribution Event
Priority:Critical
Safety constraints verified
Decision Engine
Emergency Control
Constraints:
Island capability check
Backup gen availability
Load priority
Execution Layer
Microgrid Isolation
Grid disconnect relay trigger
Island mode activation
Frequency stabilization loop
Autonomous operation
Detection Layer
Price Signal Spike
Spot price > €0.20/kWh
Peak period confirmed
Storage SOC > 40%
Event Processing
Energy Arbitrage Event
Priority:Medium
Market API confirmation
Decision Engine
Trading Logic
Constraints:
Min arbitrage margin
Grid export capacity
Settlement rules
Execution Layer
Grid Feed-in Optimization
Dynamic dispatch window
Settlement tracking
Revenue optimization
+€8.2k revenue
Message Broker
PlatformKafka Cluster
Nodes3 (replicated)
Replication factor3
Delivery semanticsExactly-once
Latency (p99)14ms
Safety & Override Logic
Safety Constraints
• Thermal limits monitoring
• Battery degradation guard
• Grid compliance rules
• Regulatory curtailment logic
Manual Override
• Operator control interface
• SCADA override enabled
• Emergency stop protocol
Forecast Engine
Weather-based PVActive
Load demand forecastActive
Market price forecastActive
Grid constraint anticipationActive
Event Audit Log (Real-time)
EVT-847214:23:45
Source: Grid Monitor
Decision: Battery dispatch
Result: Success
Compliance: ISO 50001
EVT-847114:18:32
Source: Frequency Sensor
Decision: Load shed
Result: Success
Compliance: Grid Code
EVT-847014:12:18
Source: Solar Inverter
Decision: EV priority
Result: Success
Compliance: OCPP 2.0
EVT-846914:05:09
Source: System Controller
Decision: Microgrid sync
Result: Success
Compliance: IEEE 1547
Multi-Tenant Isolation
Tenant Segmentation
Site A - Industrial8 nodes
Isolation: High
Site B - Commercial12 nodes
Isolation: Medium
Site C - Residential6 nodes
Isolation: Medium
Portfolio-Level Aggregation
Cross-tenant analytics with privacy-preserving aggregation
Detection Layer
Real-time monitoring with threshold-based triggers and condition validation
Event Processing
Kafka-based message broker with priority routing and safety validation
Decision Engine
AI-driven optimization with safety constraints and regulatory compliance
Execution Layer
Automated control with audit logging and manual override capability