Utility-Scale Performance Control Room

Grid Stability, Dispatch, Curtailment, Operator Controls

An operational dashboard view for grid-level performance: stability, curtailment, dispatch headroom, storage unit health, market intelligence, and operator actions. Built for real-time monitoring with RBAC-protected controls and incident traceability.

What it visualizes

  • system overview (capacity, net position, reserve margin, curtailment)
  • frequency/voltage/Q/ramp-rate compliance monitoring
  • storage unit SOC/health/cycles/latency and dispatch capacity
  • market signals (day-ahead/intraday) and arbitrage attribution
  • event log + operator control panel with safe overrides

Used for

  • real-time monitoring of grid-level performance
  • governing operator controls with RBAC protection
  • incident traceability and safe override management
Prototype 05

Utility-Scale Performance Dashboard

Grid-Level Intelligence & Control / Multi-Site Portfolio Management

Level A – System Overview
Installed Capacity
42.8 MW
Available Capacity
40.6 MW
Maintenance adjusted
Current Net Position
+4.6 MW
Export
Curtailment Active
1.2 MW
3 sites affected
Reserve Margin
6.3%
Level B – Grid Stability
Grid Frequency
49.98 Hz
Nominal: 50.00 Hz
Voltage Deviation
±1.1%
Within limits
Reactive Power (Q)
-3.2 MVar
Capacitive
Ramp Rate
0.8 MW/min
Limit: 2.5 MW/min
Energy Flow (24h)
Actual vs Forecast
00:0012:0023:59
Solar
Storage
Curtailment
Forecast deviation: +2.8%
Storage Units
5 Active
Unit 1
SOC: 72%Health: 93%
Rate: +1.4 MW
Cycles: 1.2
Latency: 42ms
Unit 2
SOC: 45%Health: 91%
Rate: 0 MW
Cycles: 1.8
Latency: 38ms
Unit 3
SOC: 88%Health: 95%
Rate: +0.8 MW
Cycles: 0.9
Latency: 45ms
Unit 4
SOC: 34%Health: 89%
Rate: -1.2 MW
Cycles: 2.1
Latency: 41ms
Unit 5
SOC: 61%Health: 92%
Rate: +0.6 MW
Cycles: 1.5
Latency: 39ms
Total Dispatch Capacity8.4 MW
Available Headroom3.2 MW
Round-trip Efficiency89.2%
Market Intelligence
Market Region
DE-LU
Day-Ahead Price
€142/MWh
Intraday Price
€158/MWh
Arbitrage (Today)
€8.2k
Price
Dispatch
Settlement windows
Redispatch Volume1.1 MW
Grid Health Index
98.2
Health Index
Frequency complianceOK
Voltage complianceOK
Reactive powerWarning
Protection statusActive
SCADA sync delay24ms
Node Health Status
Nodes Online26
Nodes in Warning2
Nodes in Maintenance1
Nodes in Curtailment3
Communication Loss0
System Health Index: 97.4
Storage94%
Inverters98%
Grid Sync99%
Communication Layer96%
Avg node response42ms
Last heartbeat2s ago
Event Log (Real-time)
14:23:45INFOOptimization
D-4812
Battery discharge initiated – Peak shaving
Latency: 38msAction: Auto
14:18:32WARNINGGrid Stability
D-4811
Frequency deviation 49.85 Hz
Latency: 12msAction: Auto
14:12:18INFOControl
D-4810
EV charging priority adjusted – Solar surplus
Latency: 45msAction: Auto
14:05:09INFOSystem
D-4809
Microgrid sync completed – All nodes online
Latency: 28msAction: Manual
Control Panel
RBAC Protected – Operator Level Access Required
Last action: 14:23:45 by operator_01